Cementless Total Hip Replacement System

High Rough 165 Stem

CAT. No. MS606

  • Three offset options to restore hip biomechanics
  • Tapered neck gemotry and optimized Articulere taper increase range of motion
  • Low-profile lateral shoulder design enables easy insertion in minimum invasive incision techniques, especially when using the anterior approach
  • Available in collared or no-collard options
  • Step geometry converts hoop stresses to compressive loads
Dia Length(mm)
Ø 09 130 mm
Ø 10 130 mm
Ø 11 135 mm
Ø 12 140 mm
Dia Length(mm)
Ø 13 145 mm
Ø 14 150 mm
Ø 15 155 mm

Cemented Stem Aqua

CAT. No. MS607

  • Highly polished surface reduces the shear force between the prosthesis and bone cement
  • Biplanar taper without collar converts longitudinal shear force to lateral compression load
  • Allow for slight sinking and revision surgery
  • Smooth prosthesis edges avoid stress concentration and cutting the bone cement
  • Match with the third-generation bone cement technique, paitents have no longer surviving life and better clinical results
Cemented Stem BC1
Dia Length(mm)
Ø 09 135 mm
Ø 10 140 mm
Ø 11 145 mm
Ø 12 150 mm
Dia Length(mm)
Ø 13 155 mm
Ø 14 155 mm
Ø 15 155 mm
Ø 16 160 mm

50 Total Acetabular Cup

Cementless Cup 50

CAT. No. MS608

  • The shell made of forged Ti-alloy has high strength and light specific wrieght and low elastic modulus. Medical UHMWPE has better abrasive resistance
  • Multi radius design and longitudinal grooves with taper press-fit make the shell engage tightly the bone with good anti-rotation
  • 20 degree anti-dislocation insert
  • Circle grooves increase interface with bone and enhance pull-out strength
Outer Cup Size Liner Ø Ball Head Ø
Ø42 37 22
Ø44 37 22
Ø 46 44 28
Ø48 44 28
Ø 50 45 32
Outer Cup Size Liner Ø Ball Head Ø
Ø52 45 32
Ø54 49 32
Ø56 49 36
Ø58 53 36
Ø60 53 36

Screw

Cancellous Screw

CAT. No. MS612

  • Ø 6mm
  • 20, 25, 30, 35

Liner

CAT. No. MS613

  • Ø 6mm
  • 20, 25, 30, 35
Liner Ø Ball Head Ø
37 22
44 28
45 32
49 32
49 36
53 36

Cemented Acetabular Cup

CAT. No. MS609

  • Annular Groove on the surface, increasing the contact area with bone cement, the inner edge after cutting, increasing the range of motion of the joint, redcuing the impingement with the stem
  • 20 degree anti-dislocation insert
  • Metal ring along the rim willproduce radiolucent line and helps locate presisely
Plastic Ø Head Ø
40 22
42 22
44 28
46 28
Plastic Ø Head Ø
48 28
50 28
52 28
54 28

Bipolar Cup

CAT. No. MS611

  • Bipolar cup is mae of Co-Cr-Mo alloy with mirror polish, which reduces friction coefficient to the minimum extent
  • Locking design: easy to install and avoid head dislocation. Push with the key when revision surgery is needed or the ball head should be changed
  • Two-center design ensures the hip joint the greatest motion range and the lowest wear
Bipolar Head Ø 38, 40, 42, 44, 46, 48, 50, 52, 54
Cup Size Ball Head Ø
Ø 38 22
Ø 40 22
Ø 42 28
Cup Size Ball Head Ø
Ø 44 28
Ø 46 28
Ø 48 28
Cup Size Ball Head Ø
Ø 50 28
Ø 52 28
Ø 54 28

Ball Head

CAT. No. MS610

  • Made of Co-Cr-Mo alloy; highly polished surface with extreme low friction coefficient
  • Highly accurate tehnology. All porducts are tested with three-dimensional measurement
  • Provide products ofspecific diameters and tapers according to clinical needs
  • Two tapers (12/14, 14/15) and over 10 sizes are available